Integrated raid exception detected



HDD Boot Failure Raid 1 with PERC H200A (LCI SAS 2008-IR) Controlller

Proskier871

Commendable

drtweak

Illustrious

I know this is old but just tossing my two cents out there.

One thing I liked to do is ALWAYS carry my Windows 10 OTG drive with me. It might pay off to buy the Enterprise version of windows just for this.

I keep it on a 240GB SSD, I have butt loads of programs. One of them being HD Sentinel which i reccomend EVERYONE to install on their servers as it is able to read SMART data of SCSI/SATA/SAS THOUGH RAID CONTROLERS!

I had someone who used me just as an emergency (they had their own tech who couldn’t get away) and i had to replace their motherboard on their Dell PE2950 server. It would just sit at the loading screen. SO i booted off this guy, ran my HDS, and BAM! there were 2 failing drives! (One was gone the other going out) luckly they had two RAID 5’s one drive in each RAID. So once i yanked the bad drive, which was part of the OS, it booted just fine. Their Tech guy was going to bring a new drive next morning but we made sure we did a backup for him as i died during the day.

Point is using the Windows OTG, and HDS, you can SEE what drive is bad and remove it and HOPE that it is trying to sync the GOOD drive to the BAD one and by removing it may allow it to boot.

The H200 is a low end RAID card. Also suggest everyone with a Dell to 1) Install Open Manage and 2) To install LSI MegaRAID Software if they have a PERC Card allowing RAID config to be done in windows and not though the controller BIOS all the time.

If it still doesn’t boot you can try this.

By R-Studio Recovery

Toss the drive in another PC and clone it, skipping the bac sectors, to another drive. and then toss it in and see if it boots. This SOMETIMES works, maybe doing a check disk after might help or also running the Rescue verion of Macrium Reflect and there is a Fix Boot option in one of the menus.

Источник

Troubleshooting HDD Module Failures in a RAID Volume

The two QFX3100 hard disk drive (HDD) modules are organized as a RAID 1, or mirrored configuration. If one HDD module fails or needs to be replaced, the remaining HDD module becomes the primary drive in the RAID. The QFX3100 continues to operate with only the primary drive, but the RAID does not operate optimally because there is no redundancy. Normally, the primary drive is only used in standalone mode until you replace the failed drive. You can replace the failed drive while the unit is running (hot-swap) and the RAID automatically resynchronizes the primary drive to the new drive.

The system operation is severely degraded while the drive automatically synchronizes the remaining drive to the replacement drive. Expect this synchronization process to take at least 17 hours. If you remove the primary drive before the newer drive becomes synchronized with the primary drive, you must re-create the RAID and reinstall the QFX3100 software image.

Читайте также:  При запуске властелин колец битва за средиземье выдает ошибку exception

If the primary (remaining) HDD module fails or is removed while the RAID is synchronizing, the RAID contents are lost and cannot be recovered.

The independent failure of two drives is extremely rare. When one or both HDD modules appear to fail, likely causes are:

One HDD module is not able to autocorrect, causing a hard failure. A replacement HDD module can be hot-swapped with the failed module.

Both HDD modules have been removed from the QFX3100 and moved to another QFX3100. The RAID becomes inactive and is not recognized as storage in the new location. If the RAID is inactive, you can restore it using an internal controller utility to activate the disk.

One HDD module has been removed and the new module inserted. However, before the two drives are synchronized, the primary drive is removed. In this scenario, the system loses track of the synchronization and corrupts the RAID. Once it has been corrupted, you must bring down the Director device, isolate the Director device, and use an internal controller utility to delete, re-create, and activate both disk members.

Allow the RAID to fully synchronize before removing an HDD module.

Isolating a Director Device

Before restoring an inactive RAID or restoring a corrupted RAID, intentionally isolate the Director device.

  1. Gracefully bring down the failing Director device. See Powering Off a QFX3100 Director Device.
  2. Disconnect the cable in port 0 of the failing Director device, which connects to the control plane virtual chassis.
  3. Disable the interfaces on the EX4200 or E4300 that connect the failing Director device to both Interconnect devices using the set interface disable command.

On a QFX3000-M QFabric system, disable ge-0/0/40 and ge0/0/41.

Copper or fiber EX Series VC0 interfaces:

Copper or fiber EX Series VC1 interfaces:

On a QFX3000-G QFabric system using copper connections, disable port 40 for Director Group 1 failures or port 41 for Director Group 2 failures.

Источник

LSI SAS 106x controllers will show resyncing at POST — Servers

Troubleshooting

Problem

On systems that use the following RAID controllers (LSI Logic 1064, LSI Logic 1064E, LSI Logic 1069 PCI-x controller), the following message may be displayed: Integrated RAID exception detected: Volume (00:000) is currently in state RESYNCING Enter the LSI Logic Configuration Utility to investigate!

Resolving The Problem

Source

RETAIN tip: H191738

Symptom

On systems that use the following Redundant Array of Independent Disks (RAID) controllers (LSI Logic 1064, LSI Logic 1064E, LSI Logic 1068e PCI-x, LSI Logic 1078E), the following message may be displayed:

Integrated RAID exception detected:

  • Volume (00:000) is currently in state RESYNCING
  • Enter the LSI Logic Configuration Utility to investigate!

Affected configurations

The system may be any of the following IBM servers:

  • BladeCenter HS12, type 1916, any model
  • BladeCenter HS12, type 8014, any model
  • BladeCenter HS12, type 8028, any model
  • BladeCenter HS20, type 7981, any model
  • BladeCenter HS21 XM, type 1915, any model
  • BladeCenter HS21 XM, type 7995, any model
  • BladeCenter HS21, type 1885, any model
  • BladeCenter HS21, type 8853, any model
  • BladeCenter HS22, type 1936, any model
  • BladeCenter HS22, type 7870, any model
  • BladeCenter HS22V, type 1949, any model
  • BladeCenter HS22V, type 7871, any model
  • BladeCenter HX5, type 7872, any model
  • BladeCenter LS21, type 7971, any model
  • BladeCenter LS22, type 7901, any model
  • BladeCenter LS41, type 7972, any model
  • BladeCenter LS42, type 7902, any model
  • System x3200 M2, type 4367, any model
  • System x3200 M2, type 4368, any model
  • System x3200 M2, type 9233, any model
  • System x3200 M3, type 7327, any model
  • System x3200 M3, type 7328, any model
  • System x3200, type 4362, any model
  • System x3200, type 4363, any model
  • System x3250 M2, type 4190, any model
  • System x3250 M2, type 4191, any model
  • System x3250 M2, type 4194, any model
  • System x3250 M3, type 4251, any model
  • System x3250 M3, type 4252, any model
  • System x3250 M3, type 4261, any model
  • System x3250, type 4364, any model
  • System x3250, type 4365, any model
  • System x3250, type 4366, any model
  • System x3350, type 4192, any model
  • System x3350, type 4193, any model
  • System x3400 M2, type 7836, any model
  • System x3400 M2, type 7837, any model
  • System x3400 M3, type 7378, any model
  • System x3400 M3, type 7379, any model
  • System x3500 M2, type 7839, any model

The system is configured with one or more of the following IBM options:

  • IBM 3 Gb SAS HBA v2, option 44E8700, FRU 44E8701
  • IBM SAS HBA Controller, option 25R8060, FRU 25R8071
  • LSI 1064 Integrated Controller
  • LSI 1064e Integrated Controller
  • LSI 1078e Integrated Controller
  • Paddle board with LSI 1064E SAS Controller, any FRU
  • ServeRAID-BR10i SAS/SATA Controller, option 44E8689, CRU 44E8690
  • ServeRAID-BR10il SAS/SATA Controller Kit, option 44X0411, CRU 43V7415 — Controller kit
  • ServeRAID-BR10il SAS/SATA Controller v2, option 49Y4731, CRU 49Y4737

This tip is not option specific.

This tip is not software specific.

Solution

None, this is a permanent restriction, there will be no solution.

Additional information

When first creating the logical drive, there will be an initial resync. When rebooting the machine, the above message in the Symptom field, will appear. Eventually, the resync will complete.

After running for a certain amount of time (depending on the I/O generated on the LSI controller) and rebooting, the above message will appear again. This controller will initiate a resync once the LSI algorithm hits a designated value. If there is heavy I/O, then this will happen more often. When the algorithm activates that resync, the message will appear on reboots.

On ServeRAID SCSI controller models 4, 5, 6, 7 , resync messages were not shown to the users.

Источник

Инструкция по эксплуатации Dell Serial Attached SCSI 5iR Integrated and Adapter

Страница 45

Поиск и устранение неисправностей

Adapter configuration may have

changed, reconfiguration is

(Конфигурация адаптера могла

измениться, рекомендуется реконфигурация!)

Press CTRL-C to run Dell SAS 5

C, чтобы запустить утилиту конфигурирования
Dell SAS 5. )

Запустите утилиту конфигурирования и подтвердите
конфигурацию контроллера SAS 5/iR.

Это сообщение отображается, когда BIOS ожидает
инициализации.

SAS discovery error
(Ошибка обнаружения SAS)

Вызывается сообщением микропрограммы об ошибке
обнаружения. Может сопровождаться другими подобными
сообщениями. Для получения дополнительной информации
запустите утилиту конфигурирования.

Integrated RAID exception detected:

(Обнаружено исключение Integrated RAID:)

BIOS обнаружила исключение с одним или несколькими
виртуальными дисками RAID. За дополнительной
информацией об устранении этой неисправности
рекомендуется обратиться к сообщению об ошибке “Volume
(xx:yy:zzz) is currently in state “STATE” (В настоящее время
том (xx:yy:zzz) находится в состоянии «STATE»)”.

Volume (xx:yy:zzz) is currently

(В настоящее время том

(xx:yy:zzz) находится в состоянии «STATE»)

В сообщении приводится текущее состояние указанного
виртуального диска, когда оно не является оптимальным.
Ниже перечислены возможные состояния.

• INACTIVE: виртуальный диск не активен (возможно,

это посторонний диск) или находится в одном из
указанных ниже состояний.

• DEGRADED: виртуальный диск находится

в деградированном состоянии с утраченной
избыточностью.

• RESYNCING: виртуальный диск деградировал и в

настоящее время находится в состоянии восстановления.

• FAILED: ошибка виртуального диска, он находится

в состоянии отказа.

• MISSING: виртуального диска больше нет, но его запись

Device not available at

(Устройство недоступно в)

Возможно, устройство в данное время не готово. Устройство
повторит попытку загрузки. Если проблема не устранена,
перезапустите систему.

Spinning up the device!

Сканируемое в данный момент устройство раскручивается.

Источник

Инструкция по эксплуатации Dell Serial Attached SCSI Host Bus Adapter 5i Integrated and 5E Adapter

Страница 34

Поиск и устранение неисправностей

Adapter configuration may have

changed, reconfiguration is

Press CTRL-C to run Dell SAS 5

Это сообщение появляется при перемещении в системе
нескольких HBA-адаптеров SAS 5 без надлежащего
изменения порядка загрузки в системной BIOS. Запустите
утилиту конфигурирования и выберите в BIOS нужный
порядок загрузки HBA-адаптера SAS 5.

Это сообщение отображается, когда BIOS ожидает
инициализации.

SAS discovery error

Вызывается сообщением микропрограммы об ошибке
обнаружения. Может сопровождаться другими подобными
сообщениями. Для получения дополнительной информации
запустите утилиту конфигурирования.

One or more unsupported device

Когда адаптер настроен на исключение устройств SAS или
SATA, он указывает на обнаружение устройства
неподдерживаемого типа.

SAS Address NOT programmed

on controller in slot (X)

Указывает на то, что указанный адаптер имеет адрес SAS,
равный 0. Это вызывает ошибки микропрограммы и может
быть исправлено путем перепрограммирования адреса SAS
адаптера.

Integrated RAID exception detected:

BIOS обнаружила исключение с одним или несколькими
виртуальными дисками RAID. За дополнительной
информацией об устранении этой неисправности
рекомендуется обратиться к сообщению об ошибке
“Volume (xx:yy:zzz) is currently in state
“STATE”

Volume (xx:yy:zzz) is currently

В сообщении приводится текущее состояние указанного
виртуального диска, когда оно не является оптимальным.
Ниже перечислены возможные состояния.

• INACTIVE: виртуальный диск не активен (возможно, это

посторонний диск) или находится в одном из указанных ниже

• DEGRADED: виртуальный диск находится в

деградированном состоянии с утраченной избыточностью.

• RESYNCING: виртуальный диск деградировал и в настоящее

время находится в состоянии восстановления.

• FAILED: ошибка виртуального диска, он находится

в состоянии отказа.

• MISSING: виртуального диска больше нет, но его запись

Источник

Оцените статью
toolgir.ru
Adblock
detector